SVC 820-Tankless Gas Trouble Shooting Manual Page |
93
93
99 – Error Code
Explanation:
The unit detected blockage in the venting during post-purge cycle. Blockage was detected when the demand for
hot water terminated and burner was OFF. This error code will only occur at time of shut down.
*Unit must be reset by performing reset procedure on page 21.
Possible Causes:
•
Venting
VENTING:
**REFER TO USE & CARE MANUAL**
Visually inspect venting for possible blockage and/or recirculation of exhaust.
1.
Approved Venting Materials
2.
Approved Vent Terminations
3.
Vent Lengths
4.
Location Of Vent Termination (Recirculation of exhaust)
5.
Blocked Venting
6.
Venting Not Sealed Properly