52 – Error Code
Explanation:
PGFR (Proportional Gas Flow Regulator)
malfunction. The PGFR is the only modulating valve in the
Gas Control Valve.
Diagnostic Checks:
•
PGFR
PGFR DIAGNOSTICS:
Locate PGFR valve on lower right of unit. Remove and
reinsert Molex connector with red wire and Molex
connector with black wire on PGFR. Attempt to
operate unit again.
Turn power OFF. Remove and reinsert connector “R”
on Control Board.
1
2
3
IF 52 Error Code does NOT display,
unit had a loose connection.
IF 52 Error Code IS displayed,
continue to diagnostic chart on next
page.
PGFR
Control Board
PGFR
Molex Connectors