34 – Error Code Diagnostic Chart
Check the resistance across 2 black wires
on bottom Molex:
Refer to Data Table below
Replace wiring harness for Connector “R”
on Control Board
Clean Ambient Thermistor. Retest
Thermistor. IF tests OK, the water heater
appears to be normal. Attempt to operate
unit again. IF resistance NOT OK:
Replace Ambient Thermistor
NO
YES
YES
NO
Is the resistance
to the Ambient
Thermistor OK?
Is the continuity
across all wires
OK?
Remove Molex from Connector “R” at Control Board.
Check continuity from black #3 wire at Molex
connector “R” and black wires at Blue Molex located
behind Control Board. Check continuity from blue #7
wire at Molex connector “R” and blue wire at Blue
Molex located behind Control Board
Attempt to operate unit again.
If the unit malfunctions due to an Error Code 34:
Replace Control Board
Ambient Thermistor Data Table
64DV; 84DV; 95DV:
7K – 23K Ohms
64X; 84X; 95X:
2K – 72K Ohms
H95DV; H95X:
2K – 72K Ohms
Summary of Contents for PH2-20R DVSN
Page 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Page 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Page 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...