Page SVC 820 Tankless Gas Trouble Shooting Manual
4
Specifications common to all models
Model
See specification sheets for current models and specs
Purpose
Domestic Hot Water (DHW) supply for showers, cleaning, and laundry
Rated Gas Input Btu/Hr.)
See specification sheets for current models and specs
Dimensions
See specification sheets for current models and specs
Installation
Indoor Wall Mounting
: Can be vented horizontally or vertically
Outdoor Wall Mounting
: Venting not required
Mid Efficiency
: ONLY uses Stainless steel (Category III; 316L Certified)
concentric venting for indoor installation
High Efficiency
: Uses PVC; CPVC; ABS; or Stainless Steel (Category III; 316L
Certified) venting for indoor installation
Working Water Pressure
14 PSI minimum; 150 PSI maximum
Minimum Water Flow
0.4 GPM to activate burner; can be reduced to .26 GPM once burner is activated
Maximum Water Flow
Based on 35 degree rise; See specification sheets for current models and specs
Gas Connection
3/4” NPT Male
Water Connection
3/4" NPT Male
Vent Size
Mid Efficiency: 3”/5” Concentric Vent
High Efficiency: 2” or 3” Two Pipe Venting (optional concentric vent termination)
Max Vent Length
See Use & Care Manual for each product type
Inlet Gas Pressure
Natural Gas
: Minimum 4.0” w.c. Maximum 10.5” w.c.
L.P. Gas
: Minimum 8.0” w.c. Maximum 14.0” w.c.
Hot Water Supply
Temperatures
Factory Setting
: 85F – 140F (Up to 140 with Override Adjustment)
Commercial Setting
: Up to 185F via program chip
Electrical
Rating
: 120 VAC/60Hz, 3 Amps
Wire
: Indoor Models - 3 Prong (Edison) Power Supply Cord
Outdoor Models – require field wiring
Fuse
: 3A Fuse x 2 (line voltage)
Safety Devices
Flame Rods
Overheat Film Wrap for Heat Exchanger
Heat Exchanger Thermistor (Boiling Point Safety)
Electronic Burner and Combustion Monitoring and Control
Freeze Protection
Minus 30F (Without Wind-Chill Factor) with power applied
Remote Control
Standard: Main Remote Control UMC-117 (included)
Optional: Bath Remote Control USC1-117 – 120 F Max Limit
Optional: Second Bath Remote USC2-117 – 120 F Max Limit
Only one of each type remote above can be installed on a single unit
Only one of each type remote above can be installed on multiple manifold units
Summary of Contents for PH2-20R DVSN
Page 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Page 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Page 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...