10. Press the UP arrow temperature adjustment button
several times to increase the temperature to a maximum
of 185*, see Figure 4. This will verify the unit has been
successfully converted. If the temperature does not
increase past 120 or 140, then the conversion failed,
disconnect and restore power and restart the procedure at
step 5.
11. Set the remote control to the desired operating
temperature, and restore the gas and water service to the
water heater.
12. Place/Stick Conversion Label to the front of the tankless
water heater and remove the Energy Star label. Leave the
new warranty certifi cate for the customer and discard the
original warranty certifi cate.
Available Thermostat Settings - Factory Confi guration
F
85
100
102
104
106
108
110
112
114
116
118
120
C
29
38
39
40
41
42
43
44
46
47
48
49
Residential High
Temperature
Settings
Commercial High
Temperature Settings
F
125
130
135
140
F
150
160
170
180*
185*
C
52
54
57
60
C
66
71
77
82*
85*
With this Commercial Conversion the temperature ranges
available through the thermostat control are as follows:
* Some models may be able to reach up to 180°F (82°C)
!
DANGER: Hotter water increases the potential for Hot
Water SCALDS.
Commercial Conversion in a Multi-Unit Manifold
or DUOnex™ Installation
Commercial Conversion of water heaters in a Multi-Unit
Manifold or DUOnex™ Installation requires that each
tankless water heater in the installation gets a conversion chip
installed on the Control Board, as in steps 1 through 4. After
the chip installation the Program Chip Initiation is slightly
different from a single unit conversion since in a Multi-
Unit installation there is only one remote control. Complete
the entire manifold installation before continuing with the
Commercial Conversion procedure.
A. Complete the chip installation on each water heater as in
steps 1 through 4 on the front side of this document.
B. Find the two DIP switches located at the top right hand
side of the PCB. The switch labeled “DIP1” in the top
switch.
C. Change the DIP Switch #4 setting to the “ON” position.
DO NOT alter any other DIP Switch. The LED on the
PCB is fl ashing. At the same time, the display of the
Main Remote Control starts to fl ash.
D. Press the “Max” button located at the top right hand side
of the PCB for more than 1 second. The LED on the PCB
starts illuminating continuously. At the same time, the
display of the Main Remote Control is on continuously.
E. Change the DIP Switch #4 setting back to the “OFF”
position. DO NOT alter any other DIP Switch. The LED
on the PCB will stop illuminating. At the same time, the
display of the Main Remote Control will turn off.
F. Turn on the water heater at the remote control by pressing
the power button, see fi gure 3.
G. Press the UP arrow temperature adjustment button
several times to increase the temperature to a maximum
of 185*, see fi gure 4. This will verify the system has
been successfully converted. If the temperature does
not increase past 120 or 140, then the conversion failed,
restart the procedure at step A.
H. Set the remote control to the desired operating
temperature, and restore the gas and water service to the
manifold system.
I. Place/Stick Conversion Label to the front of the tankless
water heater and remove the Energy Star label. Leave the
new warranty certifi cate for the customer and discard the
original warranty certifi cate.
Commercial Conversion in a Multi-Unit Manifold or DUOnex
™
Installation
- 157 -
Summary of Contents for PH2-20R DVSN
Page 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Page 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Page 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...