Page SVC 820 Tankless Gas Trouble Shooting Manual
30
BLOWER MOTOR DIAGNOSTICS
:
Turn power OFF. Remove and reinsert connector “G” on
Control Board. Attempt to operate unit again. IF 10
Warning Code does NOT display, unit had a loose
connection.
1
Remove 3 screws holding Blower Motor in place. Clean
Blower Motor and reassemble unit. Attempt to operate
unit again. IF 10 Warning Code does NOT display:
Blower Motor needed to be cleaned.
Turn power OFF. Remove 3 screws for Control Board
mounting bracket. Remove connectors “M”, “T”, & “G”.
Pull PCB out of way to access Blower Motor.
Locate Min & Max buttons on Control Board.
Continue to diagnostic chart on next page.