Pit+Plus

Installation Guide

Patent Pending

Summary of Contents for Little Giant Pit+Plus 9JP2V2DA1

Page 1: ...Pit Plus Installation Guide Patent Pending ...

Page 2: ...r may they play with the equipment or in the immediate vicinity If the power cord is damaged it must only be replaced by qualified personnel Keep work area clean well lit and uncluttered Keep safety labels clean and in good condition Wear safety glasses while installing or performing maintenance on pump Do not run pump dry Fill pump with water before starting or pump will be damaged Make sure all ...

Page 3: ...etting Started 2 Features 4 Start Up Procedure 5 Troubleshooting Guide 7 Replacement Parts 9 Pit Plus Jr with ECM 10 Pit Plus Jr with Floats 11 Pit Plus Sr with ECM 12 Pit Plus Sr with Floats 13 ECM 14 Maintenance 15 Warranty 17 ...

Page 4: ...ional alarm External Control Module ECM 4 The optional ECM is an advanced control switch for a sewage basin Pump Access Cover 5 The pump access cover allows access to pump for removal and installation Removal of the access cover also allows the installer to monitor operation of the level control float switch and the optional alarm float switch during installation or service Discharge and Vent Pipe...

Page 5: ... raised molded features on the bottom of the basin and reconnect discharge pipe to exit pipe with flexible coupling and band clamps Step 5 Examine level control float switch and optional alarm float if included Verify the float pole is secured to bottom of control cover and there are no obstructions that might interfere with the operation of the level control float switch or alarm float switch Not...

Page 6: ...n be made Step 8 Connect the basin discharge pipe to drain pipe A check valve not included must be installed near basin to prevent backflow into basin For best performance of check valves when handling solids install in a horizontal position or at an angle not more than 45 degrees Step 9 Connect the Pit Plus vent pipe to vent pipe Step 10 Connect piggyback plug to a 115 V outlet Plug the pump powe...

Page 7: ...outlet 4 Turn on electrical power 5 If pump operates the switch is in failure mode Pump will operate but water waste will not exit basin Blocked discharge pipe Remove blockage Blocked vent pipe Remove blockage Note Air admittance valves can create problems with sealed sewage basins They restrict the free passage of air in the vent pipe that is needed for efficient pumping Pump is air locked 1 Cons...

Page 8: ...s pump capacity Larger pump required Defective switch Disconnect switch check with ohmmeter open infinitive resistance closed zero Loose connection in level control wiring Check control wiring Pump runs but does not discharge liquid Check valve installed backwards Check flow indicating arrow on check valve body to ensure it is installed properly Check valve stuck or unplugged Remove check valve an...

Page 9: ...Premium Simplex Package Systems 9 Replacement Parts Replacement Parts Pit Plus Jr with ECM Replacement Parts Pit Plus Sr with ECM Replacement Parts Pit Plus Jr with Floats Replacement Parts Pit Plus Sr with Floats ...

Page 10: ... 2 2V2D Models 2 2V3D and 3V2D Models 1 925023 Grommet 3 3V3D Models 2 2V3D and 3V2D Models 1 13 1117617 1 4 20 x 1 Bolt 16 14 1127502 1 4 Flat Washer 16 15 925033 Cord Grommet 1 Hole For Models without Alarm 1 925014 Cord Grommet 2 Hole For Models with Alarm 1 16 116710 Stainless Band Clamp for Alarm Float For Models with Alarm 1 17 113254 Cord Clamp For Models with Alarm 1 18 945015 Fernco 3 For...

Page 11: ...D Models 1 113563 Discharge Pipe 3 2V3D and 3V3D Models 1 18 113565 2 x 6 Vent Discharge Pipe 2V2D Models 2 2V3D and 3D2V Models 1 113566 3 x 6 Vent Discharge Pipe 3V3D Models 2 2V3D and 3V2D Models 1 19 925033 Grommet 2 2V2D Models 2 2V3D and 3D2V Models 1 925023 Grommet 3 3V3D Models 2 2V3D and 3V2D Models 1 20 1117617 1 4 20 x 1 Bolt 17 21 1127502 1 4 Flat Washer 17 22 925014 Cord Grommet 2 Hol...

Page 12: ... 2 2V2D Models 2 2V3D and 3V2D Models 1 925023 Grommet 3 3V3D Models 2 2V3D and 3V2D Models 1 13 1117617 1 4 20 x 1 Bolt 16 14 1127502 1 4 Flat Washer 16 15 925033 Cord Grommet 1 Hole For Models without Alarm 1 925014 Cord Grommet 2 Hole For Models with Alarm 1 16 116710 Stainless Band Clamp for Alarm Float For Models with Alarm 1 17 113254 Cord Clamp For Models with Alarm 1 18 945015 Fernco 3 For...

Page 13: ...D Models 1 113563 Discharge Pipe 3 2V3D and 3V3D Models 1 18 113565 2 x 6 Vent Discharge Pipe 2V2D Models 2 2V3D and 3D2V Models 1 113566 3 x 6 Vent Discharge Pipe 3V3D Models 2 2V3D and 3V2D Models 1 19 925033 Grommet 2 2V2D Models 2 2V3D and 3D2V Models 1 925023 Grommet 3 3V3D Models 2 2V3D and 3V2D Models 1 20 1117617 1 4 20 x 1 Bolt 17 21 1127502 1 4 Flat Washer 17 22 925014 Cord Grommet 2 Hol...

Page 14: ...s ECM REPLACEMENT PARTS ITEM NO PART NO DESCRIPTION QTY 1 113264 ECM Housing 1 2 113263 ECM Cover 1 3 902511 Screw 10 x 1 1 8 SST 4 4 950320 Switch 1 5 108125 Diaphragm 1 6 902404 Switch Holder Screw 1 7 108202 Switch Holder 1 8 951060 Wiring Harness 115 V 18 FT 1 ...

Page 15: ...ng and remove pump Step 7 Remove discharge pipe from pump and install on replacement pump Step 8 Install replacement pump into basin Position pump so that the lower discharge pipe aligns with the basin discharge pipe Step 9 Position flexible adapter so that it is centered on the lower and upper discharge pipes and tighten band clamps Step 10 Feed power cord through the cord grommet opening and rei...

Page 16: ...odule to basin and secure with six 6 bolts Step 9 Insert cords in cord grommet and install cord grommet into the switch module Caution Remove any cord slack that might potentially interfere with control float or optional alarm float operation Step 10 Connect switch and pump to power supply ECM External Control Module Removal and Installation Step 1 Disconnect pump and switch from power supply Step...

Page 17: ...ion repair or replace defective parts Repaired or replaced parts will be returned freight prepaid by the Company 4 This warranty policy does not cover any labor or shipping charges The Company shall not be liable for any costs or charges attributable to any product testing maintenance installation repair or removal or for any tools supplies or equipment needed to install repair or remove any produ...

Page 18: ...URE TO WARN AND OR INSTRUCT LOSS OF OTHER PRODUCTS OR COSTS OF ENVIRONMENTAL REMEDIATION OR DIMINUTION IN PROPERTY VALUE THE REMEDIES OF THE PURCHASER SET FORTH HEREIN ARE EXCLUSIVE AND THE LIABILITY OF THE COMPANY SHALL NOT EXCEPT AS EXPRESSLY PROVIDED HEREIN EXCEED THE PRICE OF THE PRODUCTS UPON WHICH SUCH LIABILITY IS BASED DAMAGES AS SET FORTH IN THIS PARAGRAPH SHALL BE REASONABLY MITIGATED TO...

Page 19: ...19 NOTES ...

Page 20: ...701 7894 Pour l aide technique entrez s il vous plaît en contact 800 701 7894 Para la ayuda técnica por favor póngase en contacto 800 701 7894 www littlegiant com lgnet fele com Franklin Electric Co Inc Oklahoma City OK 73157 2010 Phone 1 800 701 7894 Fax 1 405 228 1561 ...