Start Up Procedure
Step 1
Remove finish cover and set aside.
Step 2
Remove bolts and washers from pump access cover and set cover aside.
Step 3
Observe position of pump. The pump should be upright with standoff feet located within the three
(3) integral torque stops (Figure 1).
Step 4
Verify that the pump discharge pipe is securely connected to the exit pipe (inside the basin) with
the flexible coupling. If the pump is not in the correct position or the discharge pipe is detached,
reposition pump with pump legs located within the three torque stop features (raised molded
features on the bottom of the basin) and reconnect discharge pipe to exit pipe with flexible
coupling and band clamps.
Step 5
Examine level control float switch and optional alarm float (if included). Verify the float pole is
secured to bottom of control cover and there are no obstructions that might interfere with the
operation of the level control float switch or alarm float switch.
Note:
The float pole assembly (Figure 2) is assembled at the factory to specifications for optimal
operation. The cord grips are installed for the primary and alarm float (if equipped) tethered at
specified length(s). Changing the length(s) could result in system failure. Reference the float switch
and/or alarm switch instruction manual for additional installation and operation information.