HDSL Status
91
2
Type a letter at the prompt to accomplish one of the following:
The status for the doubler unit(s) can be viewed through the alarm history menu (see See “Alarm
History” on page 92).
* A Doubler unit must be installed in the circuit to display the “S” option.
Type this letter
To get this response
A
Shows a performance history for 24 hours.
B
Shows a performance history for seven days.
R
Resets minimum and maximum margins, 24-Hour ES, 24-Hour UAS, and
24-Hour Performance History. When the prompt displays, you type <
Y>
to
confirm the reset or type <
N>
to cancel the reset.
X
Exits the current screen, and returns you to the status menu.
S
*
Shows doubler spans not seen on the current screen. The first screen shows the
span from the COT to the doubler and the second screen shows the span from the
doubler to the RT. Another screen appears when using two doublers.