Provisioning Your System
82
POTS Ground/Loop Start Configuration
1
From the Setup Menu, type
and press
. The POTS Ground/Loop Start
Configuration menu is displayed:
This menu shows that channel unit 1 (CU1) has eight POTS channels enabled, channel unit 2 (CU2)
has eight POTS ground start channels enabled, and channel unit 3 (CU3) has 4 ISDN channels
enabled.
2
To change a channel unit parameter, do one of the following:
•
Type
and press
to change the channel to loop start.
•
Type
and press
to change the channel to ground start.
3
To enable or disable a channel unit, type the number for the channel unit (CU1 - CU3) followed
by a comma, and then type the channel number (1 - 8) and press
.
Some screens are different when channel units are installed in a 19-inch or 23-inch shelf. The
example screens, where appropriate, show only a 23-inch shelf with three channel units.
Table 23. POTS Ground/Loop Start Configuration Options
Parameter
Default Value
Function
Channel
Configuration
Loop
Each POTS channel may be individually configurable as Loop Start or
Ground Start. This configuration is stored in both the COLU and the
channel card. If any one card (COLU, RTLU, COCU or RTCU) is
removed and replaced or reinserted, the Loop/Ground Start Configuration
is automatically preserved. Can be set to the following parameters:
•
LOOP: The selected channel is set for Loop Start.
•
GND: The selected channel is set for Ground Start.
D
Enter
01-SEP-97 PAIRGAIN TECHNOLOGIES INC., PG-FLEX TERMINAL 03:41:20
SYSTEM ID: PG-Flex 24 Channel System SYSTEM: 1
POTS GROUND/LOOP START CONFIGURATION
----------------------------------------------------------------------------
CU1
CU2
CU3
Channel
COT
(POTS8)
(POTS8)
(ISDN4)
RT
(POTS8)
(POTS8)
(ISDN4)
(---)
----------------------------------------------------------------------------
1
LOOP
GND
N/A
2
LOOP
GND
N/A
3
LOOP
GND
N/A
4
LOOP
GND
N/A
5
LOOP
GND
-
6
LOOP
GND
-
7
LOOP
GND
-
8
LOOP
GND
-
CTRL-X) Main Menu e(X)it
[COT] ENTER COMMAND>x
L
Enter
G
Enter
Enter
Summary of Contents for PG-Flex
Page 10: ...PG Flex System Overview 2 Figure 1 Typical PG Flex Configuration 23 Shelf shown ...
Page 24: ...PG Flex System Overview 16 ...
Page 52: ...Installing PG Flex System Hardware 44 Figure 21 Connecting the Metallic Bypass Pair ...
Page 62: ...Installing PG Flex System Hardware 54 ...
Page 66: ...Terminal Management 58 Figure 28 Connecting an ASCII Terminal to a Line Unit ...
Page 104: ...Performance Monitoring 96 ...
Page 120: ...Troubleshooting 112 ...
Page 158: ...Screen Menus and Definitions A 36 ...
Page 162: ...Acronyms and Glossary Glossary 4 ...
Page 167: ......
Page 168: ......