Craft Port
57
Connecting to a Terminal
1
Connect a standard RS-232 cable between the PG-Flex and your ASCII terminal:
•
If the PG-Flex system has a FPI-729 List 1 or FAU-728 List 2 installed, connect the
RS-232 cable to the either the alarm unit or the PGTC interface front panel (Figure 27).
•
If the PG-Flex system does not have an alarm unit or PGTC interface installed, connect the
RS-232 cable to the appropriate system line unit (Figure 28).
2
Configure your terminal to the following communications settings:
•
1200 to 9600 baud (9600 baud recommended)
•
No Parity
•
8 data bits
•
1 stop bit
•
Hardware Flow Control Off
Figure 27. Connecting an ASCII Terminal to an FPI-729 or FAU-728 List 2 Unit