PG-Flex System Overview
8
Remote Terminal Equipment
The RT Enclosure (Figure 5) is comprised of the following equipment:
•
RT enclosure
•
line unit
•
channel unit(s)
RT Enclosure
One RT Enclosure is required for each PG-Flex system, and provides mounting for one common
line unit and up to three (3) channel units, supporting up to 24 channels. The enclosures provide
termination points for subscriber circuits, power, and metallic bypass pair. AMP Quiet Front™ or
RayChem terminations, with internal gas tube protectors, are provided on the backplane for High
bit-rate Digital Subscriber Line (HDSL) and Bypass connections. Optionally, add AMP Quiet
Front termination or RayChem terminations for auxiliary power pairs when used with a PG-Flex
doubler. The enclosure can be pole or wall mounted and is environmentally sealed for outside plant
installation.
Figure 5. Remote Terminal Enclosure