PG-Flex System Overview
10
RT Channel Units
Channel units provide the interface between subscriber services (POTS, ISDN) and the PG-Flex
system’s internal pulse code modulation (PCM) bus. The RT channel units must be installed in the
same relative slot positions as the channel units on the CO-end of a PG-Flex system.
The RT channel units provide the following features:
•
64 kbps A-Law PCM encoding
•
applies ringing voltage
•
generates forward disconnect
•
generates metering tones (12 kHz, 16 kHz)
•
detects an off-hook or ring-tip condition
•
connects a subscriber loop to a metallic test pair
•
protects against secondary surges
A status LED is associated with each line to indicate whether the line is off-hook, idle, ringing, or
being tested. A common fault LED indicates a general fault has been detected on the unit
(Figure 7). Metallic test access connections to a specific line circuit are made through the Craft port
or by the CO switch applying the appropriate voltages on the subscriber line.