Installing PG-Flex System Hardware
42
Connect the HDSL Lines
Connect the HDSL lines as shown in Figure 20.
1
Connect HDSL Pair #1 onto wire-wrap pins HDSL_n_T1 (Tip) and HDSL_n_R1 (Ring) on the
shelf for system n.
2
Connect HDSL Pair #2 onto wire-wrap pins HDSL_n_T2 (Tip) and HDSL_n_R2 (Ring) on the
shelf for system n.
3
Repeat steps 1 and 2 for each system installed.
Figure 20. Connecting the HDSL Lines
For the following procedure, n is 1 for System 1, 2 for System 2, 3 for System 3, and 4 for System 4.
For ease of identification and added safety, red vinyl caps (provided) should be installed over the
HDSL wire-wrapped pins.