Installing PG-Flex System Hardware
48
Auxiliary Power Pairs
When PG-Flex is used with a doubler, wire the auxiliary power pairs to the COT shelf (Figure 9) as
follows:
1
Wire-wrap auxiliary power pair 1 to PWR_1_T1 (Tip) and PWR_1_R1 (Ring) for system n.
2
Wire-wrap auxiliary power pair 2 to PWR_2_T2 (Tip) and PWR_2_R2 (Ring) for system n.
3
Repeat steps 1 and 2 when required for systems 2, 3, and 4.
Figure 23. Installing the Auxiliary Power Pairs
For ease of identification and added safety, red vinyl caps (provided) may be installed over the
auxiliary power pairs wire-wrapped pins.