Setup Menu Screens
A-29
POTS Loop/Ground Start
From the POTS Loop/Ground Start menu, you can change a channel unit parameter to loop start or
ground start. Refer to Table A-5 for POTS ground/loop start configuration options.
Table A-5. POTS Ground/Loop Start Configuration Options
Parameter
Default Value
Function
Channel
Configuration
Loop
Each POTS channel may be individually configurable as Loop Start or
Ground Start. This configuration is stored in both the COLU and the
channel card. If any one card (COLU, RTLU, COCU or RTCU) is
removed and replaced or reinserted, the Loop/Ground Start
Configuration is automatically preserved. Can be set to the following
parameters:
•
LOOP: The selected channel is set for Loop Start.
•
GND: The selected channel is set for Ground Start.
01-SEP-97 PAIRGAIN TECHNOLOGIES INC., PG-FLEX TERMINAL 03:41:20
SYSTEM ID: PairGain PG-Flex System SYSTEM: 1
POTS GROUND/LOOP START CONFIGURATION
----------------------------------------------------------------------------
CU1
CU2
CU3
Channel
COT
(POTS8)
(POTS8)
(ISDN4)
RT
(POTS8)
(POTS8)
(ISDN4)
(---)
----------------------------------------------------------------------------
1
LOOP
GND
N/A
2
LOOP
GND
N/A
3
LOOP
GND
N/A
4
LOOP
GND
N/A
5
LOOP
GND
-
6
LOOP
GND
-
7
LOOP
GND
-
8
LOOP
GND
-
CTRL-X) Main Menu e(X)it
[COT] ENTER COMMAND>x
Summary of Contents for PG-Flex
Page 10: ...PG Flex System Overview 2 Figure 1 Typical PG Flex Configuration 23 Shelf shown ...
Page 24: ...PG Flex System Overview 16 ...
Page 52: ...Installing PG Flex System Hardware 44 Figure 21 Connecting the Metallic Bypass Pair ...
Page 62: ...Installing PG Flex System Hardware 54 ...
Page 66: ...Terminal Management 58 Figure 28 Connecting an ASCII Terminal to a Line Unit ...
Page 104: ...Performance Monitoring 96 ...
Page 120: ...Troubleshooting 112 ...
Page 158: ...Screen Menus and Definitions A 36 ...
Page 162: ...Acronyms and Glossary Glossary 4 ...
Page 167: ......
Page 168: ......