Installing PG-Flex System Hardware
30
Connect the HDSL Lines
1
Route the HDSL pairs through the strain relief on the bottom of the enclosure.
2
Terminate HDSL Pair #1 on the Quiet-Front terminals HDSL_1_T (Tip) and
HDSL_1_R (Ring).
3
Terminate HDSL Pair #2 on the Quiet-Front terminals HDSL_2_T (Tip) and
HDSL_2_R (Ring).
4
Secure with a cable tie to the bracket near the cable entrance.
Figure 13. HDSL Pair
Use 6 AWG wire to ensure a good ground connection to the FRE-765 RT enclosure.