Troubleshooting Using Front Panel LED Indications
101
Can Not Hear,
Can Not Be
Heard
•
subscriber problem
•
faulty RT or COT
channel unit
•
CO switch
1
Lift the subscriber line at the network interface and check the signal level.
If correct, refer trouble to the customer per local practice.
2
If the level is too low, check the level at the RT. If the level is correct at the
RT, check the pair between the RT and the network interface. If the level is
too low at the RT, replace the RT channel unit.
3
If the level is still too low, reinsert the original RT channel unit.
4
Check the level at the COT coming from the CO switch. If it is correct,
replace the COT channel unit. If it is not correct, refer the problem to the
CO regarding the switch.
5
If the level is still not correct, reinsert the original COT channel unit.
Contact PairGain “Technical Support” on page 113.