Acme Packet 4500 Hardware Installation and Maintenance Guide
69
6 Maintenance
Introduction
This chapter explains Acme Packet 4500 hardware maintenance procedures. This
chapter also provides hardware alarm information.
System Shut Down
Although several user-replaceable components of the Acme Packet 4500 are hot-
swappable, some Acme Packet 4500 maintenance procedures require that you shut
down the system.
Before you shut down or restart the Acme Packet 4500, ensure that there are no
active calls in progress. Procedures to reroute call and network traffic around the
Acme Packet 4500 are outside the scope of this guide.
You can set the Acme Packet 4500 to reject all incoming calls from your system with
the
set-system-state
command. When set to offline, this command lets calls in
progress continue uninterrupted, but no new calls are admitted.
After all call processing has stopped, you can power off your Acme Packet 4500.
Shutting down the system is appropriate when you are replacing a physical interface
card, power supply, or are removing the Acme Packet 4500 from the equipment rack.
Rejecting
Incoming Calls
To reject all incoming calls on the Acme Packet 4500:
1.
In Superuser mode, type
set-system-state offline
and press <Enter>.
ACMEPACKET# set-system-state offline
Setting system state to going-offline, process will complete when all
current calls have completed
ACMEPACKET#
After all call processing has stopped, you must halt the operating system before you
power off your Acme Packet 4500 when running S-CZ software images. Shutting
down the system is appropriate when you are replacing a physical interface card,
storage device, power supply, or are removing the Acme Packet 6300 from the
equipment rack.
Shutting down the
Acme Packet 4500
1.
In superuser mode, type
halt
and then press <Enter>, then answer
y
followed
by <Enter> at the halt confirmation prompt.
ACMEPACKET# halt
---------------------------------------------------------------------
WARNING: you are about to halt the SD!
---------------------------------------------------------------------
Halt this SD [y/n] ? : y
Preparing for system shutdown
Summary of Contents for Acme Packet 4500
Page 1: ...Acme Packet 4500 Hardware Installation and Maintenance Guide Formerly Net Net 4500 April 2015...
Page 6: ...vi Acme Packet 4500 Hardware Installation and Maintenance Guide...
Page 10: ...4 Acme Packet 4500 Hardware Installation and Maintenance Guide ABOUT THIS GUIDE...
Page 14: ...8 Acme Packet 4500 Hardware Installation and Maintenance Guide SAFETY...
Page 38: ...32 Acme Packet 4500 Hardware Installation and Maintenance Guide GRAPHIC DISPLAY...
Page 74: ...68 Acme Packet 4500 Hardware Installation and Maintenance Guide STARTUP...
Page 110: ...104 Acme Packet 4500 Hardware Installation and Maintenance Guide GLOSSARY...
Page 114: ...108 Acme Packet 4500 Hardware Installation and Maintenance Guide I INDEX...