94
Se
ct
io
n 5
Communica
tions
Comma
nds
RFID System
Operation Manual
Section 5
Communications
■
1:N Communications
Less than 242 Characters in Read Data
More Than 240 Characters in Read Data
Data code specification
Specifies the type of code in which to send the read data in the response.
A: ASCII
H: Hexadecimal
R/W Head No.
Specifies the Read/Write Head with which to communicate.
1: Read/Write Head 1
2: Read/Write Head 2
Read area start address
Specifies the first address from which to read data from the Data Carrier as a four-digit hexadeci-
mal number.
Specifiable range: 0000H to FFFFH
No. of read bytes
Specifies the number of bytes of data to read from the Data Carrier as a four-digit hexadecimal
number. Up to 8192 bytes can be read with one command.
Specifiable range: 0001H to 2000H
• ASCII specification: 8192 bytes (8192 characters)
• Hexadecimal code specification: 8192 bytes (16384 characters)
End code
Indicates the results of command execution. An end code of 00 is returned for a normal end.
Refer to
for more information.
Read data
The data read from Data Carrier memory. The number of characters will be the same as the number of
read bytes for ASCII data and twice the number of read bytes for hexadecimal data.
x
x
E
R
x
x
A/H
1/2
x
x
2
1
1
4
4
No. of read bytes
2
*
CR
Terminator
x
x
x
x
2
FCS
3
Controller No.
x
@
x
Command code
Read area start address
Data code
specifica-
tion
R/W Head No.
Command
Response
x
E
R
x
0
0
x
x
2
2
n
2
*
C R
x
x
2
FC S
3
x
@
x
Controller No.
Command
code
End code
Read data
Terminator
ER
CR
CR
CR
CR
00
FCS
FCS
FCS
FCS
@Controller No.
@Controller No.
@Controller No.
@Controller No.
240 characters
1 frame = 250 characters max.
240 characters
240 characters or less
Read data 1
Read data 2
Read data n-1
Read data n
*
:
Frame 1
Frame 2
Frame n-1
Frame n
20 ms
A/H
1/2
ER
FCS
@Controller No.
Start address
No. of read bytes
*CR
Host device
ID Controller
Summary of Contents for V600 Series
Page 50: ...48 Section 2 Wiring RFID System Operation Manual Section 2 Installation and Wiring MEMO ...
Page 72: ...70 Section 4 Write Command Memory RFID System Operation Manual Section 4 Function ...
Page 138: ...136 Section 5 End Codes RFID System Operation Manual Section 5 Communications MEMO ...