130
Se
ct
io
n 5
Host
De
vi
ce
Comman
ds
RFID System
Operation Manual
Section 5
Communications
COMMUNICATIONS CONDITIONS SETTING (TR)
TR sets conditions for serial communications. After modifying a setting it is necessary to restart the ID
Controller or execute the ABORT command (XZ) to enable operating with the modified setting.
Setting communications conditions with this command is enable only when internal settings are enabled (i.e., when
SW3 pin 1 is ON).
■
1:1 Communications
Baud rate setting
Sets the baud rate.
0: 1,200 bps
1: 2,400 bps
2: 4,800 bps
3: 9,600 bps
4: 19,200 bps
5: 38,400 bps
Default setting: 2,400 bps
Data length setting
Sets the data length.
7: 7 bits
8: 8 bits
Default setting: 7 bits
Parity check setting
Sets the parity check method.
0: No parity
1: Odd parity
2: Even parity
Default setting: Even parity
Stop bit setting
Sets the number of stop bits.
1: 1 bit
2: 2 bits
Default setting: 2 bits
End code
Indicates the results of command execution.
00: Normal end
Refer to
for more information.
Command
Command code
T
R
x
x
2
1
2
*
CR
Terminator
x
x
Baud
rate
settin
g
1
Data
len
g
th
settin
g
1
Parity
check
settin
g
1
Stop bit
settin
g
Response
Command code
T
R
0
0
2
2
2
*
CR
Terminator
End code