Section 5
Communications
■
1:N Communications
Baud rate setting
Sets the baud rate.
0: 1,200 bps
1: 2,400 bps
2: 4,800 bps
3: 9,600 bps
4: 19,200 bps
5: 38,400 bps
Default setting: 2,400 bps
Data length setting
Sets the data length.
7: 7 bits
8: 8 bits
Default setting: 7 bits
Parity check setting
Sets the parity check method.
0: No parity
1: Odd parity
2: Even parity
Default setting: Even parity
Stop bit setting
Sets the number of stop bits.
1: 1 bit
2: 2 bits
Default setting: 2 bits
End code
Indicates the results of command execution.
00: Normal end
Refer to
for more information.
Command
Command code
T
R
x
x
2
1
2
*
CR
Terminator
x
x
Baud
rate
settin
g
1
Data
len
g
th
settin
g
1
Parity
check
settin
g
1
Stop bit
settin
g
2
x
x
FCS
3
Controller No.
x
@
x
Response
Command code
T
R
0
0
2
2
2
*
CR
Terminator
End code
2
x
x
FCS
3
Controller No.
x
@
x