138
Sec
tion 6
Diag
nost
ic Func
tions
RFID System
Operation Manual
Section 6
Troubleshooting
Diagnostic Functions
Types of Errors
■
Fatal Operation Errors
If a CPU error or internal memory error occurs, the RUN/RST indicator will go OFF and the RUN output
will turn OFF. If an internal memory error occurs, the COM indicator will also light red.
If an antenna power supply voltage error occurs, the RUN/RST indicator will light green. The RUN
output will not turn OFF.
■
Non-fatal Operation Errors
If an error occurs in communications between the ID Controller and host device or in communications
between a Read/Write Head and Data Carrier, the error code will be displayed on the monitor display.
(Assuming the ID Controller is in Error Code Display Mode.) Up to 30 error records will be saved in the
error log in the ID Controller and can be read using commands from the host device.
Indicator and Output Status during Operation
Status
Indicators
Monitor
display
Output terminals
RUN
BUSY ERROR OUT1 OUT2
Test
RUN
Data Carrier communica-
tions bein
g
processed
Data Carrier communica-
tions processin
g
interval
Normal Data Carrier
communications
Error in Data Carrier
communications
Waitin
g
for data
send/receive
Sendin
g
/receivin
g
data
Normal Data Carrier
communications
Host communica-
tions error
Error in Data Carrier
communications
Fatal
error
CPU error
Antenna power supply
error
Internal memory error
Emer
g
ency
stop
External reset input ON
: Not lit
: Lit
g
reen
: Lit yellow
: Lit red
USR: Set usin
g
the CONTROLLER CONTROL command.
---
---
End code
Error code
---
---
End code
Error code
Error code
---
92
93
---
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
---
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
---
---
---
---
---
OFF
USR
OFF
OFF
OFF
OFF
OFF
OFF
---
---
---
---
---
OFF
USR
OFF
OFF
OFF
OFF
OFF
OFF
RUN/RST
COMM
COMM1
COMM2
NORM1/ERR1
NORM2/ERR2