51
RFID System
Operation Manual
Se
ct
io
n 3
Switch Settings
Section 3
Preparing Communications
Factory Settings
Name
Factory
setting
Description
More
information
SW1
Controller Number Switch 1 (Upper digit: 0 to 9)
0
Controller number 00
SW2
Controller Number Switch 2 (Lower digit: 0 to 9)
0
SW3 pin 1
DIP switch/internal setting selector
OFF
DIP switches enabled
SW3 pin 2
Baud rate setting 1
OFF
Baud rate: 2,400 bps
SW3 pin 3
Baud rate setting 2
OFF
SW3 pin 4
Baud rate setting 3
OFF
SW3 pin 5
Data length setting
OFF
Data length: 7 bits
SW3 pin 6
Parity setting 1
OFF
Parity: Even
SW3 pin 7
Parity setting 2
OFF
SW3 pin 8
Stop bit setting
OFF
Stop bits: 2 bits
SW3 pin 9
Communications protocol setting
OFF
1:1
SW3 pin 10
Reserved.
OFF
Not used.
SW4 pin 1
Priority mode switch
OFF
Communications distance
priority
SW4 pin 2
Verify setting
OFF
Verification enabled
SW4 pin 3
Display switch
OFF
End code display
SW4 pin 4
Lower trigger execution
OFF
No lower trigger
SW4 pin 5
Reserved.
OFF
Not used.
SW4 pin 6
Test switch
OFF
Test stopped
SW4 pin 7
Reserved.
OFF
Not used.
SW4 pin 8
TEST head specification
OFF
Read/Write Head 1 designated
SW4 pin 9
TEST command specification
OFF
Read test
SW4 pin 10
Reserved.
OFF
Not used.
SW5
Mode switch
OFF
RUN mode
SW6
Terminating resistance switch
OFF
Terminating resistance not
connected.