55
RFID System
Operation Manual
Se
ct
io
n 3
Switch Settings
Section 3
Preparing Communications
■
Setting the Mode Switch
■
Setting the Terminating Resistance
When more than one ID Controller is connected in series to a single host device, the terminating resis-
tance must be turned ON at the nodes (ID Controller or host device) on both ends of the main cable
and turned OFF at the rest of the nodes. Operation will not be stable if the terminating resistance is not
set correctly.
The terminating resistance switch connects and disconnects the built-in terminating resistance.
SW5
Description
OFF
RUN mode
ON
MAINTENANCE mode
SW6
Description
OFF
Terminating resistance not connected.
ON
Terminating resistance connected.
Summary of Contents for V600 Series
Page 50: ...48 Section 2 Wiring RFID System Operation Manual Section 2 Installation and Wiring MEMO ...
Page 72: ...70 Section 4 Write Command Memory RFID System Operation Manual Section 4 Function ...
Page 138: ...136 Section 5 End Codes RFID System Operation Manual Section 5 Communications MEMO ...