background image

Your Global Automation Partner

Instructions for Use

PD20-UHF

RFID Handheld

Summary of Contents for PD20-UHF

Page 1: ...Your Global Automation Partner Instructions for Use PD20 UHF RFID Handheld...

Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Page 3: ...Transmission Frequency 11 5 Connection 12 5 1 Battery Charging 12 5 2 Connect the handheld to the mobile device 12 6 Commissioning 13 7 Operation 14 7 1 Start the Turck RFID app 14 7 2 Home Screen Ov...

Page 4: ...0 F 49 208 4952 264 more turck com www turck com 9 Eliminating Interference 42 10 Maintenance 43 10 1 Carrying out a Firmware Update 43 11 Repair 43 11 1 Returning Devices 43 12 Disposal 43 13 Techni...

Page 5: ...avoided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor or moderate injury if not avoided NOTICE NOTICE indicates a situation which may lead to property damage...

Page 6: ...a AUS Australia BRA Brazil KOR Korea RUS Russia SGP Singapore PER Peru The device versions for Australia Brazil Korea Russia Singapore and Peru are available on re quest 2 2 Scope of Delivery The scop...

Page 7: ...The Turck product database contains software tools for programming configuration or commissioning data sheets and CAD files in numerous export formats You can access the product database at the follo...

Page 8: ...following table shows the operating frequency of the devices Type code Operating frequency PD20 UHF EU R 865 7 867 5 MHz PD20 UHF NA R 902 75 927 25 MHz PD20 UHF CHN R 920 25 924 75 MHz PD20 UHF AUS R...

Page 9: ...xtended stay within the area of radiation of UHF devices may be harmful to health Maintain a minimum distance from the actively radiating surface of the UHF read write head Region Max permissible tota...

Page 10: ...dheld with UHF antenna n Connection to the host device via audio port n incl Turck RFID app iOS Android for reading and writing of tags n Custom application software on request n Wifi 802 11a b g n an...

Page 11: ...application in regions other than the accred ited ones is not permitted Since BL ident UHF tags do not emit their own radio waves they may be used worldwide In order to achieve the biggest possible c...

Page 12: ...device should be charged for at least 2 hours before initial commissioning Connect the Micro USB plug connector to the handheld Connect the USB plug connector to the USB port of a PC or a laptop or C...

Page 13: ...e for Android and iOS devices in the Play Store or the App Store Search for Turck RFID Android devices Download the Turck RFID app from the Play Store and install it on your mobile device IOS devices...

Page 14: ...g you must use a charger that supplies 600 mA or less 7 1 Start the Turck RFID app Open the Turck RFID app on your mobile device Set the volume of the mobile device to maximum a The handheld can be op...

Page 15: ...a The EPCs of the detected tags are displayed and can be edited Further information on this is provided in the section Reading and writing data Fig 4 Turck RFID app Scan screen Interrupting a scan Pr...

Page 16: ...n Selection of the memory bank on the tag n Start byte for the required action hexadecimal and decimal formats selectable n Number of bytes If All is selected as many bytes are read as are available...

Page 17: ...out access pass word permanently writable Tag can be written with and without access password The permanently writable state cannot be changed Write restricted Tag can only be written with the access...

Page 18: ...tarted from the start screen or from the Scan screen Starting the read operation from the start screen If no EPC is selected the device reads the first tag found This will usually be the closest tag b...

Page 19: ...V02 00 2018 11 19 Select the memory bank to be read Fig 8 Selecting the memory bank Select the required format for displaying the start byte Fig 9 Selecting the format...

Page 20: ...s the current start byte and enter a new start byte in the following window Fig 10 Selecting the start byte Select the number of bytes to be read If Some is selected enter the number in the fol lowing...

Page 21: ...V02 00 2018 11 21 Selecting the display format for the read data Fig 12 Selecting the display format Press Read Fig 13 Button Read...

Page 22: ...EPC list a The Read Write screen is opened Select the memory bank to be read Select the required format for displaying the start byte Specify the start byte for the read operation Press the current st...

Page 23: ...an screen Starting the write operation from the start screen If no EPC is selected the device writes to the first tag found This will usually be the closest tag but this is not guaranteed This mode sh...

Page 24: ...bH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Select the memory bank to be written Fig 16 Selecting the memory bank Select the required format for displaying the start byte F...

Page 25: ...tart byte in the subsequent window Fig 18 Selecting the start byte Select the number of bytes to be written If Some is selected enter the number in the fol lowing window If All is selected as many byt...

Page 26: ...ation 26 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Select the display format for the write data Fig 20 Selecting the display format Press Read Fig 21 Button...

Page 27: ...V02 00 2018 11 27 Adjust the data in the table Fig 22 Write data Press Write Fig 23 Write a The handheld starts the write operation The written data is displayed on the screen...

Page 28: ...e memory bank to be written Select the required format for displaying the start byte Specify the start byte for the write operation Press the current start byte and enter a new start byte in the subse...

Page 29: ...the handheld and mobile terminal device as well as temperature diagnostics Icon Description No handheld connected to mobile terminal device Connection establishment to the handheld Handheld connected...

Page 30: ...0 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Icon Description Temperature warning Handheld hot Temperature warning Handheld overheated no communication with t...

Page 31: ...Shows the version of the Turck RFID app type serial number firmware and battery status of the handheld n PD20 password Password for the handheld n Email address for using the send function in Scan mo...

Page 32: ...T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com 8 2 Setting the scan screen The menu for the configuration of the Scan screen is divided into 4 areas n Send data n Scan n Display n Sec...

Page 33: ...n a placeholder Refer to the HTTP POST Placeholders table Time for sending Batch Each tag Batch Sends after the scan a POST with the data of all tags located in the POST data of the handheld one line...

Page 34: ...ation at which the tag was found Format Latit ude longitude only avail able if Location is activ ated under Scanning x HTTP POST Examples Read individual tag EPC URL http myserver com findOne grokkerI...

Page 35: ...05060708091011 1122343445566778899AABB FC02030405060708091012 1122343445566778899AACC FC02030405060708091013 1122343445566778899AADD HTTP POST Return data If required data can be output via HTTP POST...

Page 36: ...Subject of the email The subject can contain the following placeholders n GROKKER_ID Serial number of the handheld n LOCALTIME Date and time local n GMTTIME Date and time GMT n NUM_TAGS Number of tags...

Page 37: ...n screen Set the data transmission via the Clipboard according to the following table Default values are shown in bold type Parameters Selection Description Data format CSV JSON CSV Read data in CSV f...

Page 38: ...ace for setting the number of bytes to be read from the TID memory The data is read without an offset If the set number of bytes cannot be read the tag is not reported Location Yes The location of eac...

Page 39: ...e false true resets the existing scan config uration before a new configuration is transferred startScanning true false true starts the scan operation Method for sending data destination http Send dat...

Page 40: ...eters volume 0 100 Volume n 0 silent n 100 Maximum volume tagType uhf UHF tags hf HF tag not available for PD20 UHF geigerMode yes Geiger In Geiger mode the hand held outputs a signal each time a tag...

Page 41: ...fault 0 no restart maxTagsToFind Max number of EPCs to be read default 0 no limit epcDisplay Epc Hexadecimal display default Ascii ASCII AsciiLeadingZeros ASCII with leading zeros Icar15 lcar15 Icar16...

Page 42: ...k the connections of the handheld and the mo bile terminal device for faults If there are no faults there is a device malfunction Device faults may be caused by several factors n The handheld is not c...

Page 43: ...return acceptance conditions when returning the device to Turck 11 1 Returning Devices If a device has to be returned bear in mind that only devices with a decontamination declara tion will be accepte...

Page 44: ...put power 5 30 dBm adjustable Antenna polarization simulates circular Memory depending on the connected host device Display depending on the connected host device Battery capacity 1800 mAh Communicati...

Page 45: ...ormity Hans Turck GmbH Co KG hereby declares that the radio equipment type PD20 UHF EU R cor responds to Directive 2014 53 EU The full text of the EU Declaration of Conformity is available on the Inte...

Page 46: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100001275 2018 11 100001275...

Reviews: