6 Hardware Specifications of E3X-ECT
E3X-ECT EtherCAT Sensor Communication Unit Instraction Manual
6-2 General S
p
ec
ification
s
6
6-2
General Specifications
This section explains the general specifications of the E3X-ECT EtherCAT Slave Unit.
Item
Specification
Unit power supply voltage
20.4 to 26.4 VDC (24 VDC
15% to +10%)
I/O power supply voltage
20.4 to 26.4 VDC (24 VDC
15% to +10%)
Noise immunity
Conforms to IEC 61000-4-4, 2 kV (power line).
Vibration resistance
Malfunction 10 to 60 Hz with amplitude of 0.7 mm, 60 to 150Hz and 50 m/s
2
in each
of X, Y, and Z directions for 80 minutes
Shock resistance
150 m/s
2
with amplitude of 0.7 mm
(3 times each in 6 directions on 3 axes)
Dielectric strength
500 VAC (between isolated circuits)
Insulation resistance
20 M
or more (between isolated circuits)
Ambient operating
temperature
0 to 55
C
Ambient operating
humidity
25% to 85% (with no condensation)
Ambient operating
atmosphere
No corrosive gases
Storage temperature
25 to 65
C
Storage humidity
25% to 85% (with no condensation)
Mounting method
35-mm DIN track mounting
Summary of Contents for Sysmac E3X-ECT
Page 1: ...E3X ECT EtherCAT Sensor Communication Unit Operation Manual E413 E1 ...
Page 3: ......
Page 4: ...E3X ECT EtherCAT Sensor Communication Units Operation Manual Revised February 2012 ...
Page 5: ......
Page 29: ...1 EtherCAT Network 1 8 E3X ECT EtherCAT Sensor Communication Unit Instration Manual ...
Page 51: ...4 Installation and Wiring 4 12 E3X ECT EtherCAT Sensor Communication Unit Instraction Manual ...
Page 67: ...5 EtherCAT Communications 5 16 E3X ECT EtherCAT Sensor Communication Unit Instraction Manual ...
Page 137: ...A Appendix A 36 E3X ECT EtherCAT Sensor Communication Unit Instraction Manual ...
Page 139: ...Revision 2 E3X ECT EtherCAT Sensor Communication Unit Instraction Manual ...
Page 140: ......