19
CX-Profibus Configurator
Section 1-4
CS1W
-P
RM
21 /
CJ1W
-P
RM
21 DT
M
Device setup
Device setup allows the user to:
• Set the Unit number related to the actual PROFIBUS-DP Master
unit.
• Configure the communication link between the PC and the Unit.
This function invokes the User Interface of CX-Server.
• Test the Units communication link and to read out the Unit’s infor-
mation.
Master setup
This function allows the user to define the Unit’s behavior in case of
• a network malfunction.
• a PLC mode change between PROGRAM mode and MONITOR/
RUN mode.
It also allows the definition of Auto-addressing, which simplifies I/O
data mapping.
Bus parameter setup
The bus parameter setup allows the selection of baud rate and cal-
culation and editing of specific bus parameters.
Slave area setup
The Slave area setup allows the user to define the I/O Data map-
ping of the I/O Data from each of the Slave stations on to the PLC
memory areas. This can be done automatically, but also allows edit-
ing by the user.
Monitoring functions
• Master status read-out.
• Slave status and slave diagnostics read-out.
• Read-out of the Unit’s error log.
Support functions
• Context sensitive help functions.
G
ene
ri
c Sl
a
v
e DTM
General functions
The Generic Slave DTM reads the contents of a specific GSD file
located in a special sub-directory, and displays the setup options to
the user. It supports
• GSD file revisions 1 and 2 (PROFIBUS-DP functionality).
• GSD file revisions 3 (PROFIBUS-DPV1 functionality).
I/O Configuration setup
The I/O Configuration setup function allows:
• Selection of Station address.
• Enable/disable watchdog.
• Overview of available I/O modules.
• Selection of I/O modules, including Addition, Insertion and
Removal of multiple modules.
Parameter setup
The Parameter setup function:
• Setting of common as well as module dependent parameters.
• Setting of PROFIBUS-DP Extension parameters.
Group setting
The Group setup function allows definition of the group to which the
associated Slave station will belong.
Monitoring functions
The Monitoring functions provides a display of
• Standard Slave diagnostics flags.
• Extended diagnostics messages.
Support functions
• Context sensitive help functions.
• Multi-language support.
Item
Specification
Summary of Contents for SYSMAC CJ1W-PRM21
Page 2: ...iv...
Page 36: ...22 Basic Operating Procedure Section 1 5...
Page 52: ...38 Defining PROFIBUS DP in the Software Section 2 5...
Page 112: ...98 Allocated CIO Area Words Section 4 2...
Page 122: ...108 Command Response Reference Section 5 2...
Page 160: ...146 Replacing the Unit Section 7 8...
Page 174: ...160 Appendix...
Page 180: ...166 I O Data Conversions Appendix D...
Page 186: ...172 Configurator Error and Warning Messages Appendix E...
Page 187: ...173 Index...
Page 188: ...174 Index...
Page 190: ...176 Revision History...