157
Appendix
Module Identifier byte
Channel Identifier byte
Bit
Name
Description
00
~
05
Module number
These bits contain the number of the configuration module, to which the channel,
reporting diagnostics belongs. The module number ranges from 0 to 63.
06
~
07
Reserved
Fixed to 10.
The combination of bit 6 and 7 indicate the type of diagnostics, i.e. 10 indicates
Channel related diagnostics data.
Bit
Name
Description
00
~
05
Channel number
These bits contain the number of the channel, which reports the diagnostics. The
channel number ranges from 0 to 63.
06
~
07
I/O type
Bit 6 and 7 indicate the type of I/O channel, from which the diagnostics data is
sent.
• 00: Reserved
• 01: Input
• 10: Output
• 11: Input/Output
1 0
7
6
5
4
3
2
1
0
Module number
Module Identifier byte
Channel Identifier byte
7
6
5
4
3
2
1
0
Channel number
I/O type
7
6
5
4
3
2
1
0
Error type number
Error Identifier byte
Channel size type
Summary of Contents for SYSMAC CJ1W-PRM21
Page 2: ...iv...
Page 36: ...22 Basic Operating Procedure Section 1 5...
Page 52: ...38 Defining PROFIBUS DP in the Software Section 2 5...
Page 112: ...98 Allocated CIO Area Words Section 4 2...
Page 122: ...108 Command Response Reference Section 5 2...
Page 160: ...146 Replacing the Unit Section 7 8...
Page 174: ...160 Appendix...
Page 180: ...166 I O Data Conversions Appendix D...
Page 186: ...172 Configurator Error and Warning Messages Appendix E...
Page 187: ...173 Index...
Page 188: ...174 Index...
Page 190: ...176 Revision History...