![background image](http://html1.mh-extra.com/html/omron/omnuc-r88d-uep-series/omnuc-r88d-uep-series_user-manual_744167168.webp)
6-16
Note 1. Cn-04 (speed loop gain) is factory-set for three times the load inertia. Therefore, if the load
inertia is extremely small, some oscillation may occur. If it does, then lower Cn-04 to 20 or
less.
Note 2. After the settings Cn-24 (Electronic gear ratio G1 (numerator)) or Cn-25 (Electronic gear ratio
G2 (denominator)) have been made, they become effective when the power is turned on
again after having been cut off. (Check to see that the LED display has gone off.)
Supplementary Materials
Chapter 6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com