3-10
3. Repeat steps 1 and 2 above as required.
4. Save the data in memory by pressing the DATA Key.
5. With this, the parameter setting operation is complete. Pressing the DATA Key at this point will bring
back the parameter number display.
3-4-2 Setup Parameter Contents (Cn-01 and Cn-02)
j
Setup Parameter No. 1 (Cn-01)
Item
Bit no.
Factory
setting
Setting
Explanation
Sequence input sig-
l
i hi
0
0
0
Servo turned ON or OFF by Run command (externally input).
q
g
nal switching
1
Servo always ON.
1
0
---
Not used.
2
1
0
Enables forward drive prohibit input (POT).
1
Permits always-forward drive.
3
1
0
Enables reverse drive prohibit input (NOT).
1
Permits always-reverse drive.
4
0
---
Not used.
5
1
---
Not used.
6
1
---
Not used.
7
1
---
Not used.
Abnormal stop
8
0
0
The dynamic brake decelerates to stop the Servomotor at the
time of overtraveling.
1
The maximum torque decelerates to stop the Servomotor at the
time of overtraveling.
9
0
---
Not used.
Deviation counter
i h S
OFF
A
0
0
Clear counter for alarms occurring while Servo is OFF
with Servo OFF
1
Do not clear counter for alarms occurring while Servo is OFF
b
1
---
Not used.
C
0
---
Not used.
d
0
---
Not used.
E
0
---
Not used.
F
0
---
Not used.
Note 1. Do not change the settings of bits 1, 4 through 7, 9, or b through F of setup parameter 1
(Cn-01).
Note 2. These parameters become effective only after power is reset. Confirm that the indicators go
out before turning power back on. (Check to see that the LED display has gone off)
Operation
Chapter 3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com