3-13
D
Displaying with Mounted-type (R88A-PR03U)
1. Press the MODE/SET Key to go into settings mode (
cn
).
2. Press the Up and Down Keys to display the desired user parameter number.
The number will be incremented or decremented each time the Up or Down Key is pressed.
3. Press the DATA Key to display the setting of the specified parameter.
4. Press the DATA Key again to return to the parameter number display.
D
Parameter Display Example
c n 0 4
0 0 0 8 0
[1]
[2]
[5]
[4]
DATA
DATA
Parameter Number Display
Data Display
j
Setting User Parameters
First, use the previous procedure to display the settings of the user parameter. Then use the following
procedures to set user parameters.
D
Making Settings with Handy-type (R88A-PR02U)
1. Use the Right and Left Keys to select the digit that is to be set. The digit for which the value can be
changed will blink.
2. Press the Up and Down Keys to change the value of the digit.
3. Repeat the previous two steps as required to set the parameter.
4. Press the MODE/SET or DATA Key. The parameter will be set and the display will blink.
5. Press the DATA Key again to return to the parameter number display.
6. Repeat steps 1 through 5 above as required to set other parameters.
Note 1. Settings can also be made by pressing only the Up and Down Keys in stead of using steps 1.
and 2. This will enable setting digits higher than the one that is blinking. Use whichever meth-
od is faster for the number of digits that need to be set.
Note 2. The Down Key can be pressed when all digits higher than the blinking one are zeros to set the
minimum value in the setting range.
Note 3. The fifth digit (i.e., the leftmost digit) cannot be made to blink by pressing the Left Key. The fifth
digit can be set from the fourth digit. For example, to set “10000,” press the Left Key to make
the fourth digit blink and then press the Up Key again once the fourth digit reaches “9.” The
fifth digit will change to “1” and the fourth digit will change to “0.”
D
Making Settings with Mounted-type (R88A-PR03U)
1. Using the Up and Down Keys, set the data. If the keys are held down, the numbers will change 10 at
a time. If the keys are held down even longer, the numbers will change 100 and then 1,000 at a time.
2. Press the MODE/SET Key (or the DATA Key). The parameter will be set and the display will blink.
3. Pressing the DATA Key again will bring back the parameter number display.
4. Repeat steps 1 through 4 above as required to set other parameters.
Operation
Chapter 3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com