143
Inspection and Cleaning
Section 6-3
Cautions on replacing the NT11
When replacing the NT11 after discovering a fault during inspections, note
the following points:
• Be sure to switch the power OFF before replacement.
• After replacement, check that the new NT11 is not subject to the same
error.
• If a faulty unit is returned for repairs, write as detailed a description of the
fault as possible and send this description together with the unit to the
OMRON address indicated on the back cover of this book.
!Caution
Do not disassemble for repairs or modification. Otherwise, the product may
malfunction.
!Caution
The disposal of the unit may be regulated by national or local authorities. Dis-
pose of them in accordance with the laws and regulations of the relevant
country and local authority.
Ambient environmental
conditions
Ambient temperature (temper-
ature in the operation panel)
0 to 50
°
C
Thermometer
Ambient humidity
(humidity in the operation
panel)
35% to 85%
Hygrometer
Presence/absence of dust
Dust must not be settled
Visual inspection
Mounting conditions
Looseness of mounting brack-
ets etc.
To be no looseness
Accessory tools
Connector connections of con-
necting cable
To be fully inserted and locked,
with no looseness
Looseness of screws in exter-
nal wiring
To be no looseness
Phillips screwdriver
Conditions of external connect-
ing cables
Faults such as incipient dis-
connections.
Visual inspection
Components with limited
lives
Brightness of the backlight
Must be sufficiently bright.
Backlight life: 50,000 hours
Visual inspection
Point Inspected
Inspection Details
Criterion
Inspection Instrument
Summary of Contents for NT11 - 01-2004
Page 1: ...USER S MANUAL Cat No V084 E1 01 NT11 Programmable Terminal ...
Page 2: ...NT11 Programmable Terminal User s Manual Produced January 2004 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 13: ...xiv Safety Precautions 3 ...
Page 27: ...14 Before Operating Section 1 6 ...
Page 71: ...58 Connecting a Printer Section 2 8 ...
Page 119: ...106 Daily Report Display History Printing Function Section 4 10 ...
Page 157: ...144 Inspection and Cleaning Section 6 3 ...
Page 162: ...149 Appendix B Dimensions Body NT11 SF121 B EV1 38 2 7 5 218 203 113 98 ...
Page 163: ...150 Dimensions Appendix B ...
Page 165: ...152 Transporting and Storing the NT11 Appendix C ...
Page 183: ...170 Revision History ...
Page 186: ...NT11 Programmable Terminal Cat No V084 E1 01 USER S MANUAL ...