6-2-5
Number of Process Values to Average
Set the number of process values to average according to the following
tables and flow diagram. The setting range available for averaging is shown
below.
Setting period
1
128
!
2
256
4
512
8
!
1024
16
2048
!
32
4096
64
8192
!
Given a setting, the time required for sampling is shown below.
Sampling period
1
3.1 ms
128
130 ms
2
4.2 ms
256
270 ms
4
6.2 ms
512
530 ms
8
10 ms
1024
1.1 s
16
19 ms
2048
2.1 s
32
35 ms
4096
4.2 s
64
68 ms
8192
8.4 s
! $