6-2-3
Operating Parameter 3
Holding Data (TIMING Input)
Normal
When the K3TS is set to
on operating parameter 3, the TIMING input is
not effective, and the K3TS continues data sampling.
Sampling Hold
When the K3TS is set to
on operating parameter 3, the K3TS retrieves
the data on the rising edge of the TIMING input and holds the data until the
rising edge of the next TIMING input signal.
TIMING input
Input waveform
0 (v)
ON
OFF
Power ON
In this period, the displayed
process value is “
”.
First TIMING input after power is 0N.
Sampling hold value
Maximum Hold
When the K3TS is set to
on operating parameter 3, the K3TS continues
data sampling while the TIMING input is ON. When the TIMING input is OFF,
the K3TS displays the maximum value of the data that has been sampled
and holds the value until the next TIMING input signal is OFF.
Maximum hold value
Input waveform
0 (V)
ON
OFF
TIMING input
In this period, the displayed
process value is “
”.
First TIMING input after power is ON.
Power ON
! $
Section 6-2