63
Multi-function I/0
Chapter 5-9
5-9
Multi-function I/0
5-9-1
Multi-function Input
The J7AZ incorporates four multi-function input terminals (S2 through S5).
Inputs into these terminals have a variety of functions according to the
application.
Multi-function Input (n36 through n39)
Note
Do not set values outside the above setting ranges.
n36
Multi-function Input 1 (S2)
Changes during
operation
No
Setting
range
2 to 8, 10 to 22
(see note)
Unit of
setting
1
Default setting
2
n37
Multi-function Input 2 (S3)
Changes during
operation
No
Setting
range
0,2 to 8, 10 to 22
(see note)
Unit of
setting
1
Default setting
5
n38
Multi-function Input 3 (S4)
Changes during
operation
No
Setting
range
2 to 8, 10 to 22
(see note)
Unit of
setting
1
Default setting
3
n39
Multi-function Input 4 (S5)
Changes during
operation
No
Setting
range
2 to 8, 10 to 22, 34, 35
(see note)
Unit of
setting
1
Default setting
6