58
Setting the Frequency Reference
Chapter 5-5
No multi-step speed reference 3 settings will be required if only frequency
references 1 through 4 are used, for example. Any multi-step speed reference
not set is regarded as turned-OFF input.
Setting the Inching Frequency Command (n29)
The inching frequency command must be set as multi-function input in order
to use the inching frequency command.
Note
1.
The value will be set in 0.1-Hz increments if the frequency is less than 100
Hz and 1-Hz increments if the frequency is 100 Hz or over.
2.
In order to use the inching frequency command, one of the n36 through
n39 parameters for multi-function input must be set to 10 as an inching
frequency command. Parameter n29 is selectable by turning on the multi-
function input set with the inching frequency command. The inching
frequency command takes precedence over the multi-step speed
reference (i.e., when the inching frequency command is ON, all multi-step
speed reference input will be ignored).
Frequency reference
Multi-step speed
reference 1
(Set value: 6)
Multi-step speed
reference 2
(Set value: 7)
Multi-step speed
reference 3
(Set value: 8)
Frequency reference 1
OFF
OFF
OFF
Frequency reference 2
ON
OFF
OFF
Frequency reference 3
OFF
ON
OFF
Frequency reference 4
ON
ON
OFF
Frequency reference 5
OFF
OFF
ON
Frequency reference 6
ON
OFF
ON
Frequency reference 7
OFF
ON
ON
Frequency reference 8
ON
ON
ON
n29
Inching Frequency Command
Changes during
operation
Yes
Setting
range
0.0 to max. frequency
Unit of
setting
0.01 Hz
(see note 1)
Default setting
6.0
Summary of Contents for J7 series
Page 12: ...XII...
Page 15: ...1 CHAPTER 1 Overview 1 1 Function 2 1 2 Nomenclature 3...
Page 54: ...40 Outline of Operation Chapter 3 2...
Page 102: ...88 Other Functions Chapter 6 7...
Page 158: ...144 Option Specifications Chapter 9 3...
Page 159: ...145 CHAPTER 10 List of Parameters List of Parameters 146...
Page 172: ...158 List of Parameters Chapter 10...
Page 173: ...159 CHAPTER 11 Using the Inverter for a Motor Using the Inverter for a Motor 160...