39
Outline of Operation
Chapter 3-2
Example of Paramter Settings
Note
1.
To cancel the set value, press the Mode Key instead. The parameter
number will be displayed.
2.
There are parameters that cannot be changed while the Inverter is in
operation. Refer to the list of parameters. When attempting to change such
parameters, the data display will not change by pressing the Increment or
Decrement Key.
3.
Any RUN command input will be ignored while the Parameter Setting
(PRGM) indicator is lit. To enable a RUN command, first turn the RUN
command OFF and then press the Mode Key to display an item that has a
green indicator (FREF to MNTR). Then input the RUN command again.
Key sequence
Indicator
Explanation
Display
example
Power ON
Press the Mode Key repeatedly until the PRGM
indicator is lit.
Use the Increment or Decrement Key to set the
parameter number.
Press the Enter Key.
The data of the selected parameter number will be
displayed.
Use the Increment or Decrement Key to set the data.
At that time the display will flash.
Press the Enter Key so that the set value will be entered
and the data display will be lit. (see note 1)
The parameter number will be displayed.
In approximately
1 s.
Cancels set data.
In approximately 1 s.
Summary of Contents for J7 series
Page 12: ...XII...
Page 15: ...1 CHAPTER 1 Overview 1 1 Function 2 1 2 Nomenclature 3...
Page 54: ...40 Outline of Operation Chapter 3 2...
Page 102: ...88 Other Functions Chapter 6 7...
Page 158: ...144 Option Specifications Chapter 9 3...
Page 159: ...145 CHAPTER 10 List of Parameters List of Parameters 146...
Page 172: ...158 List of Parameters Chapter 10...
Page 173: ...159 CHAPTER 11 Using the Inverter for a Motor Using the Inverter for a Motor 160...