28
Wiring
Chapter 2-2
Wiring Method
1.
Loosen the terminal screws with a thin-slotted screwdriver.
2.
Insert the wires from underneath the terminal block.
3.
Tighten each terminal screw firmly to a torque specified in the previous
tables.
Note
1.
Always separate the control signal line from the main circuit cables and
other power cables.
2.
Do not solder the wires to the control circuit terminals. The wires may not
contact well with the control circuit terminals if the wires are soldered.
3.
The end of each wire connected to the control circuit terminals must be
stripped for approximately 5.5 mm.
4.
Connect the shield wire to the ground terminal of the CIMR-J7AZ. Do not
connect the shield wire to the device side being controlled.
5.
Be sure to insulate the shield wire with tape so that the shield wire will not
come into contact with other signal wires or equipment.
Applying excessive torque may damage
the terminal block. If the tightening torque
is insufficient, homever, wires may dis-
connect.
Note
Thin-slotted screwdriver
Terminal block
Solderless terminal or
wire without soldering.
Wire
Strip the end for approximately
5.5 mm if no solderless
terminal is used.
Summary of Contents for J7 series
Page 12: ...XII...
Page 15: ...1 CHAPTER 1 Overview 1 1 Function 2 1 2 Nomenclature 3...
Page 54: ...40 Outline of Operation Chapter 3 2...
Page 102: ...88 Other Functions Chapter 6 7...
Page 158: ...144 Option Specifications Chapter 9 3...
Page 159: ...145 CHAPTER 10 List of Parameters List of Parameters 146...
Page 172: ...158 List of Parameters Chapter 10...
Page 173: ...159 CHAPTER 11 Using the Inverter for a Motor Using the Inverter for a Motor 160...