13
Wiring
Chapter 2-2
Main Circuit Terminals
Note
The maximum output voltage corresponds to the power supply input voltage
of the Inverter.
Symbol
Name
Description
R/L1
Power Supply input terminals
CIMR-J7AZ2
_
: 3-phase 200 to 230 V AC
CIMR-J7AZB
_
: Single-phase 200 to 240 V AC
CIMR-J7AZ4
_
: 3-phase 380 to 460 V AC
Note
Connect single-phase input to terminals R/L1 and S/L2.
S/L2
T/L3
U/T1
Motor output terminals
3-phase power supply output for driving motors.
CIMR-J7AZ2
_
: 3-phase 200 to 230 V AC
CIMR-J7AZB
_
: 3-phase 200 to 240 V AC
CIMR-J7AZ4
_
: 3-phase 380 to 460 V AC
V/T2
W/T3
+1
Connection ter1 and +2:
DC reactor connection terminals
+1 and –:
DC power supply input terminals
Connect the DC reactor for suppressing harmonics to terminals
+1 and +2.
When driving the Inverter with DC power, input the DC power to
ter1 and –.
(Te1 is a positive terminal.)
+2
–
Ground terminal
Be sure to ground the terminal under the following conditions.
CIMR-J7AZ2
_
: Ground at a resistance of 100
Ω
or less.
CIMR-J7AZB
_
: Ground at a resistance of 100
Ω
or less.
CIMR-J7AZ4
_
: Ground at a resistance of 10
Ω
or less, and connect
to the power supply’s neutral phase to conform to EC Directives.
Note
Be sure to connect the ground terminal directly to the
motor frame ground.
Summary of Contents for J7 series
Page 12: ...XII...
Page 15: ...1 CHAPTER 1 Overview 1 1 Function 2 1 2 Nomenclature 3...
Page 54: ...40 Outline of Operation Chapter 3 2...
Page 102: ...88 Other Functions Chapter 6 7...
Page 158: ...144 Option Specifications Chapter 9 3...
Page 159: ...145 CHAPTER 10 List of Parameters List of Parameters 146...
Page 172: ...158 List of Parameters Chapter 10...
Page 173: ...159 CHAPTER 11 Using the Inverter for a Motor Using the Inverter for a Motor 160...