Vision System FH/FZ5 Series
User’s Manual (Z340)
MeasureStart
Allows input of the measurement trigger.
Format
MeasureStart
Parameter
None.
Return value
None.
Description
Allows input of the measurement trigger and input of communication commands, and changes to the
measurement allowed state.
After setting the measurement prohibited state with the MeasureStop function, execute this macro function to
return to the measurement allowed state.
After executing the MeasureStart function, be sure to execute the MeasureStop function. If the MeasureStop
function is not executed or the MeasureStart function is executed without executing the MeasureStop
function, unexpected operation may occur.
There are macro functions that can and cannot be executed in the measurement allowed state and in the
measurement prohibited state. For details, refer to the explanations of the macro functions and usage
cautions.
If input of the measurement trigger is allowed, measurement-in-progress signals such as the BUSY signal
turn OFF.
Usage Cautions
• Execute this macro function when the BUSY signal or other measurement in progress signal is ON and
measurement is prohibited. (Reference:
Summary of Contents for fh-1 series
Page 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Page 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 881: ...WWW NNC IR...