
WWW.NNC.IR
Macro Reference
533
8
App
end
ice
s
Vision System FH/FZ5 Series
User’s Manual (Z340)
GetImageWindow
Get the state of the image window.
Format
[Scene Control Macro / Communication Command Macro]
GetImageWindow <windowNo>, <locationX>, <locationY>, <width>, <height>, <unitNo>,
<subNo>, <magnification>, <originX>, <originY>, <update>, <visible>
[Unit Macro]
GetImageWindow <locationX>, <locationY>, <width>, <height>, <unitNo>, <subNo>,
<magnification>, <originX>, <originY>, <update>, <visible>
Parameter
Return value
None.
Description
Gets the state of the image window specified in the <windowNo> parameter. When this macro function is
used with the unit macro, the state of the image window displayed using the MEASUREDISPI subroutine is
set.
In the <locationX> parameter and <locationY> parameter, specify the variables that store the relative
coordinate values from the upper left coordinates of the gotten image container window to the upper left
Parameter
name
Data type
Description
<windowNo> Integer type
Image window number to get the status
<locationX>
Integer type
Upper left X coordinate value of the image window
<locationY>
Integer type
Upper left Y coordinate value of the image window
<width>
Integer type
Width of the image window
<height>
Integer type
Height of the image window
<unitNo>
Integer type
Processing unit number of the target processing unit to display
<subNo>
Integer type
Sub-image number of the target image to display
<magnification>
Double
precision real
number data
type
Display magnification
<originX>
Integer type
Upper left X coordinate of the image display relative to the upper left coordinate of the
image window.
<originY>
Integer type
Upper left Y coordinate of the image display relative to the upper left coordinate of the
image window
<update>
Integer type
Update timing of image window
0: Every measurement (Image mode Freeze)
1: Only when an overall judgement result is NG at the time of measurement (Last NG
image).
2: Only when a target processing unit is NG at the time of measurement.
3: Always updated (through display)
<visible>
Integer type
Setting of whether to display
0: Window invisible
1: Window visible
Summary of Contents for fh-1 series
Page 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Page 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 881: ...WWW NNC IR...