![background image](http://html1.mh-extra.com/html/omron/fh-1-series/fh-1-series_user-manual_742686395.webp)
WWW.NNC.IR
Macro Reference
393
8
App
end
ice
s
Vision System FH/FZ5 Series
User’s Manual (Z340)
SetUserSubr
outine
Register a user-defined function
that has been defined in the
external DDL file
Debug
Command
OK
OK
OK
OK
Reference:
X
Details (p.739)
SetVar
Sets all variables with the
specified variable names
Others
OK
OK
OK
OK
Reference:
X
Details (p.741)
Sin
Gets the sine of the specified
expression
Arithmetic
Calculation
OK
OK
OK
OK
Reference:
X
Details (p.743)
Sqr
Determines the square root
Arithmetic
Calculation
OK
OK
OK
OK
Reference:
X
Details (p.745)
StartTimer
Starts the elapsed time
measurement
Others
OK
OK
OK
OK
Reference:
X
Details (p.746)
Stop
Stops program execution
Debug
Command
OK
OK
OK
OK
Reference:
X
Details (p.747)
Str$
Converts a numeric value in the
numeric character string
String
Operation
OK
OK
OK
OK
Reference:
X
Details (p.749)
Str2$
Converts a value to a numeric
character string in the specified
formats
String
Operation
OK
OK
OK
OK
Reference:
X
Details (p.751)
SystemReset Reboots the Sensor Controller
Others
---
---
OK
---
Reference:
X
Details (p.754)
Tan
Gets the tangent of the specified
expression
Arithmetic
Calculation
OK
OK
OK
OK
Reference:
X
Details (p.755)
Time$
Reads out the clock time from
the internal clock
Arithmetic
Calculation
OK
OK
OK
OK
Reference:
X
Details (p.757)
Timer
Gets the elapsed time
Others
OK
OK
OK
OK
Reference:
X
Details (p.759)
TotalJudge
Gets the total judgement result
Processing unit
control
OK
---
---
OK
Reference:
X
Details (p.761)
TransformAn
gle
Applies the calibration result and
position correction amount in the
angle value
Processing unit
control
OK
---
---
OK
Reference:
X
Details (p.763)
TransformAr
ea
Applies the calibration result and
position correction amount in the
area value
Processing unit
control
OK
---
---
OK
Reference:
X
Details (p.765)
TransformDis
t
Applies a calibration result and
position correction amount to a
distance value
Processing unit
control
OK
---
---
OK
Reference:
X
Details (p.767)
TransformLin
e
Applies the calibration result and
position correction amount to a
line component value
Processing unit
control
OK
---
---
OK
Reference:
X
Details (p.769)
TransformXY
Applies the calibration result and
position correction amount to
coordinate values
Processing unit
control
OK
---
---
OK
Reference:
X
Details (p.771)
Try Catch
End Try
Detects an error occurrence and
executes an exception process
General
instruction
OK
OK
OK
OK
Reference:
X
Details (p.773)
UCase$
Converts an lower case letter to
a upper case letter
String
Operation
OK
OK
OK
OK
Reference:
X
Details (p.775)
Command
Name
Function
Classification
Unit
Calculat
ion
Macro
Scene
Control
Macro
Commu
nication
Comma
nd
Macro
Unit
Macro
References
Summary of Contents for fh-1 series
Page 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Page 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 881: ...WWW NNC IR...