Macro Reference
402
Vision System FH/FZ5 Series
User’s Manual (Z340)
Debug Commands
Others
Command
Function
References
Call
Executes the registered user-defined function.
Reference:
X
Details (p.421)
Cont
Resumes execution of the program after it has been
stopped.
Reference:
X
Details (p.436)
Debug
Set the program execution form and information output
method.
Reference:
X
Details (p.456)
DebugPrint
Outputs debug information to the system status console
window.
Reference:
X
Details (p.458)
List
Outputs all or a part of program list in the system status
console window.
Reference:
X
Details (p.597)
Outputs data in the system status console window.
Reference:
X
Details (p.639)
SetStop
Sets the conditions for stopping program execution.
Reference:
X
Details (p.723)
SetUserSubroutine
Register a user-defined function that has been defined in
the external DDL file.
Reference:
X
Details (p.739)
Stop
Stops program execution.
Reference:
X
Details (p.747)
VarList
Outputs a list of the values of the specified variables in the
system status console window.
Reference:
X
Details (p.796)
Command
Function
References
ElapsedTime
Gets the elapsed time since starting the measurement.
Reference:
X
Details (p.508)
ExecuteImageLogging
Executes image logging.
Reference:
X
Details (p.517)
ExitFzProcess
Terminate the Sensor Controller.
Reference:
X
Details (p.519)
RaiseOptionEvent
Notifies option events to the UI screen.
Reference:
X
Details (p.647)
Rem
Put a comment in the program.
Reference:
X
Details (p.657)
RenumUnitNo
Gets the processing unit number after flow edit.
Reference:
X
Details (p.660)
ScreenCapture
Saves the capture of the screen.
Reference:
X
Details (p.693)
SetVar
Sets all variables with the specified variable names.
Reference:
X
Details (p.741)
StartTimer
Starts the elapsed time measurement.
Reference:
X
Details (p.746)
SystemReset
Reboots the Sensor Controller.
Reference:
X
Details (p.754)
Timer
Gets the elapsed time.
Reference:
X
Details (p.759)
VarPop
Restores the value of the variables that are saved
temporarily.
Reference:
X
Details (p.798)
VarPush
Saves the value of the variables that are saved
temporarily.
Reference:
X
Details (p.801)
VarSave
Saves the values of the variables in the scene data.
Reference:
X
Details (p.804)
Wait
Pauses the program process for the specified amount of
time elapses.
Reference:
X
Details (p.806)
Summary of Contents for fh-1 series
Page 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Page 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 881: ...WWW NNC IR...