![background image](http://html1.mh-extra.com/html/omron/fh-1-series/fh-1-series_user-manual_742686358.webp)
WWW.NNC.IR
Macro Reference
356
Vision System FH/FZ5 Series
User’s Manual (Z340)
UdpPlcLinkM
PLC Link (MELSEC QnU/Q/QnAS) communication
IoModule identification name
UdpPlcLinkM
Overview
This is a module is for sending and receiving commands and data by Ethernet PLC Link protocol.
System data
PLC Link data
Area classification
Identification
Meaning
Initial value
enableDhcp
Enable DHCP
0: Disabled
1: Enabled
0
ipAddress
IP address of the system
10.5.5.100
subnetMask
Subnet mask
255.255.255.0
defaultGateway
Gateway address
10.5.5.110
dns
DNS server
10.5.5.1
delayCount
Output IP address
0.0.0.0
portNo
Input port No.
9600
Identification
Meaning
Initial value
commandArea
Command area Area
Data register
commandMemoryAddress
Command area Address
0
responseArea
Response area Area
Data register
responseMemoryAddress
Response area Address
100
outputArea
Data Output area Area
Data register
outputMemoryAddress
Data Output area Address
200
handshake
Handshaking
1
responseTimeout
Retry interval [ms]
10000
responseTimeout2
Retry interval 2 [ms]
1000
Area classification name
Area classification number
Data register
168
File register
175
Link register
180
Summary of Contents for fh-1 series
Page 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Page 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 881: ...WWW NNC IR...