Remotely Operating the Controller (Remote Operation)
163
4
Using Tools
Vision System FH/FZ5 Series
User’s Manual (Z340)
Differences from Local Operation and Limitations
There is no fundamental difference between local operation on the Sensor Controller and a remote operation.
The remote operation PC windows, however, are not the windows of the Sensor Controller themselves, and
thus, the following types of operational differences can be caused.
Major differences are listed as follows:
Functions to be noted
Description
Sensor Controller side
Remote operation PC side
Controller restart
Automatically restart
The Controller automatically restarts, while the
remote operation PC waits to be shut down
manually.
Operation mode
All modes can be executed.
All modes, except for the single-line high-
speed mode, can be executed.
Screen capture
The controller windows can be captured.
The controller windows are captured (not the
remote PC windows).
Date-time setting
The system date and time on the controller are
changed.
The system date and time on the remote
operation PC are changed.
Image display
Displays the camera images and figures, etc.
Displays the camera images and figures, etc.
with low pixels.
Unit Macro, Unit
Calculation Macro,
Customize I/O Command
Program editing is allowed.
Program editing is not allowed.
Number of Image Panes
24 max. (Image Pane numbers 0 to 23)
16 max.
Layout change
Changes in layout settings will be reflected to
the actual layout after the layout switches.
Changes in layouts settings will be reflected to
the actual layout immediately after finalizing
the layouts edit. The displays on the Sensor
Controller side and the remote operation PC
side will not be consistent before the layout
switch is performed on the sensor controller.
• The remote recovery dialog box may be hidden behind a window in the non-stop adjustment mode and the multi-line
random trigger mode, both of which contain two windows. Press [Alt+Tab] to switch between the windows.
• The remote operation communications will be disconnected if a network setting (such as the IP address, subnet mask,
and default gateway) on the Sensor Controller is modified using the remote operation function. Restart FZ_FH
Remote Operation Tool to establish the connection again. The connection may fail immediately after a network setting
has been changed. Please wait for a while before reconnecting.
IMPORTANT
Summary of Contents for fh-1 series
Page 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Page 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 881: ...WWW NNC IR...