![background image](http://html1.mh-extra.com/html/omron/fh-1-series/fh-1-series_user-manual_742686231.webp)
WWW.NNC.IR
Basic Knowledge For Macro Customize
Functions
229
5
Optimizing Scene
s (
M
ea
su
re
men
t Flo
w
s)
(M
acr
o
Custo
m
ize
Fu
ncti
ons)
Vision System FH/FZ5 Series
User’s Manual (Z340)
System Status Transitions and Possibility of Execution
There are processes that cannot be executed in certain system statuses in a macro customize program.
The following types of system status exist.
The relation between sensor controller system statuses and execution timing is shown below.
In some cases it is possible to change the measurement prohibited state and measurement acceptance state
while in a subroutine. For details, refer to Exclusive Control in a Process.
Reference:
Exclusive Control in a Process (p.234)
Execution During Screen Transitions
Some types of macro customize program execution timing occur in relation to screen transitions.
The following types of screen transitions exist.
Status type
Description
Measurement
prohibited state
Measurement instructions and communication commands cannot be accepted in this state.
The measurement prohibited state generally occurs during startup, as well as changes of
measurement flow, processing unit and system settings, and when executing a process or operation.
In the measurement prohibited state, the BUSY signal or similar status signal turns ON.
Measurement
acceptance state
Measurement instructions and communication commands can be accepted in this state.
In the measurement accepted state, the BUSY signal or similar status signal turns OFF.
Execution timing of subroutine
Pre-defined subroutine
name
System status
❍
: Can be executed
✕
: Cannot be executed
Measurement
prohibited state
Measurement
acceptance state
Program initialization
*MCRINIT
❍
✕
Measurement initialization
*MEASUREINIT
❍
✕
Measurement execution
*MEASUREPROC
✕
❍
View
Screen display
*MEASUREDISPI
❍
❍
Text display
*MEASUREDISPT
❍
❍
Graphic display
*MEASUREDISPG
❍
❍
Measurement flow update
*RENUMPROC
❍
✕
Measurement result clear
*CLEARMEASUREDATA
❍
✕
Original screen
New screen
Description
Splash screen
Main screen
Transition from splash screen at startup to main screen.
Main screen
Flow edit screen
Menu settings screen
Tool screen
Properties screen
Transition from main screen to other screens.
Flow edit screen
Main screen
Transition from flow edit screen to main screen.
Properties screen
Transition from flow edit screen to properties screen of processing unit.
Menu settings screen
Main screen
Transition from menu settings screen to main screen.
Tool screen
Main screen
Transition from tool screen to main screen.
Properties screen
Transition from tool screen to properties screen of processing unit.
Properties screen
Main screen
Transition from properties screen of processing unit to main screen.
Flow edit screen
Transition from properties screen of processing unit to flow edit
screen.
Summary of Contents for fh-1 series
Page 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Page 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 881: ...WWW NNC IR...