WWW.NNC.IR
Macro Reference
561
8
App
end
ice
s
Vision System FH/FZ5 Series
User’s Manual (Z340)
Example
Gets the read letter "A" with the OCR processing unit (Processing Unit number 5) using the unit calculation
macro processing unit and converts the letter into a hexadecimal value. The read character string can be
gotten with External Reference Data number 20
The result is shown below.
Useable Modules
Unit Calculation Macro / Scene Control Macro / Communication Command Macro / Unit Macro
Supported Versions
Version 3.50 or later
Related Items
Rem Get the measurement result of the processing unit.
GetUnitData 5, 20, CHARA1$
Rem Convert the character to the character code.
CODE& = Asc(CHARA1$)
Rem Convert the character code to the hexadecimal value in character string format.
CHARA2$ = Hex$(CODE&)
CHARA1$ = "A"
CODE& = 65
CHARA2$ = 41
Asc (Reference:
X
Details (p.413))
Chr$ (Reference:
X
Details (p.427))
GetUnitData (Reference:
X
Details (p.552))
LCase$ (Reference:
X
Details (p.589))
Left$ (Reference:
X
Details (p.591))
Len (Reference:
X
Details (p.593))
Mid$ (Reference:
X
Details (p.621))
Piece$ (Reference:
X
Details (p.637))
Right$ (Reference:
X
Details (p.664))
Str$ (Reference:
X
Details (p.749))
Str2$ (Reference:
X
Details (p.751))
UCase$ (Reference:
X
Details (p.775))
Val (Reference:
X
Details (p.794))
Summary of Contents for fh-1 series
Page 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Page 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 881: ...WWW NNC IR...