Setting the Operation Mode
272
Vision System FH/FZ5 Series
User’s Manual (Z340)
The following processing items are supported in the single-line high-speed mode:
*1: The [Subtract only] measurement mode is not supported.
*2: Images from odd numbered measurements and from even numbered measurements are logged in separate folders.
OK:Supported processing item, RST: Processing item with restricted support, ---:Unsupported processing item
Processing item
Support
Processing item
Support
Processing item
Support
Camera Image Input
OK
Glue Bead Inspection
OK
Statistics
---
Camera Image Input FH
OK
Position Compensation
OK
Reference Calib Data
OK
Camera Image Input HDR
OK
Filtering
OK
Position Data Calculation
OK
Camera Image Input HDR Lite
OK
Back Ground Suppression
OK
Stage Data
OK
Camera Switching
OK
Brightness Correct Filter
OK
Robot Data
OK
Measurement Image
Switching
OK
Color Gray Filter
OK
Vision Master Calibration
---
Search
OK
Extract Color Filter
OK
PLC Master Calibration
---
Flexible Search
OK
Anti-Color Shading
OK
Convert Position Data
OK
Sensitive Search
OK
Stripes Removal Filter II
OK
Movement Single Position
OK
ECM Search
OK
Polar Transformation
OK
Movement Multi Points
OK
EC Circle Search
OK
Trapezoidal Correction
OK
Detection Point
OK
Ec Corner
OK
Machine Simulator
OK
Camera Calibration
OK
Ec Cross
OK
Image Subtraction
RST(*1) Data Save
OK
Shape Search II
OK
Advanced Filter
OK
Conditional Branch
OK
Classification
OK
Panorama
OK
End
OK
Edge Position
OK
Calculation
OK
DI Branch
OK
Edge Pitch
OK
Line Regression
OK
Control Flow Normal
---
Scan Edge Position
OK
Circle Regression
OK
Control Flow PLC Link
---
Scan Edge Width
OK
Precise Calibration
OK
Control Flow Parallel
---
Circular Scan Edge Position
OK
User Data
OK
Control Flow Fieldbus
---
Circular Scan Edge Width
OK
Set Unit Data
OK
Selective Branch
OK
Color Data
OK
Get Unit Data
OK
Data Output
OK
Gravity and Area
OK
Set Unit Figure
OK
Parallel Data Output
OK
Labeling
OK
Get Unit Figure
OK
Parallel Judgement Output
OK
Label Data
OK
Trend Monitor
---
Fieldbus Data Output
OK
Defect
OK
Image Logging
RST(*2) Result Display
OK
Precise Defect
OK
Image Conversion Logging
RST(*2) Display Image File
OK
Fine Matching
OK
Data Logging
OK
Display Last NG Image
---
Character Inspection
OK
Elapsed Time
OK
OCR
OK
Date Verification
OK
Wait
OK
OCR User Dictionary
OK
Model Dictionary
OK
Focus
OK
2D Codes
OK
Iris
OK
Circle Angle
OK
Unit Macro
OK
Shape Search III
OK
Unit Calculation Macro
OK
Intersection
OK
Parallelize
OK
Barcode
OK Parallelize
Task
OK
Summary of Contents for fh-1 series
Page 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Page 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 881: ...WWW NNC IR...