![background image](http://html1.mh-extra.com/html/omron/fh-1-series/fh-1-series_user-manual_742686391.webp)
WWW.NNC.IR
Macro Reference
389
8
App
end
ice
s
Vision System FH/FZ5 Series
User’s Manual (Z340)
Len
Gets the length of the specified
character string
String
Operation
OK
OK
OK
OK
Reference:
X
Details (p.593)
Line Input#
Reads the data of one line from
the file
File Control
OK
OK
OK
OK
Reference:
X
Details (p.595)
List
Outputs all or a part of program
list in the system status console
window
Debug
Command
OK
OK
OK
OK
Reference:
X
Details (p.597)
LoadBackup
Data
Loads the scene group
0 data
Data Save/
Load
---
OK
OK
---
Reference:
X
Details (p.599)
LoadScene
Loads the scene data
Data Save/
Load
---
OK
OK
---
Reference:
X
Details (p.601)
LoadSceneG
roup
Loads the scene group data
Data Save/
Load
---
OK
OK
---
Reference:
X
Details (p.603)
LoadSystem
Data
Loads the system data
Data Save/
Load
---
OK
OK
---
Reference:
X
Details (p.605)
LoadUnitDat
a
Loads the processing unit data
Data Save/
Load
---
OK
OK
---
Reference:
X
Details (p.607)
Log
Gets the natural logarithm
Arithmetic
Calculation
OK
OK
OK
OK
Reference:
X
Details (p.609)
Lsqumeth
Gets the approximate straight
line from the coordinates of
multiple points using the least
squares method
Arithmetic
Calculation
OK
OK
OK
OK
Reference:
X
Details (p.610)
Measure
Executes measurement
processing
Measurement
control
---
OK
OK
---
Reference:
X
Details (p.612)
MeasureDisp
G
Executes display of the
measurement result of the
processing unit
Processing unit
control
---
---
---
OK
Reference:
X
Details (p.614)
MeasureId$
Gets the measurement
identification
Processing unit
control
OK
---
---
OK
Reference:
X
Details (p.615)
MeasureProc
Executes measurement
processing in a processing unit
Processing unit
control
---
---
---
OK
Reference:
X
Details (p.616)
MeasureStart
Allows input of the
measurement trigger
Measurement
control
---
OK
OK
---
Reference:
X
Details (p.617)
MeasureStop
Prohibits input of the
measurement trigger
Measurement
control
---
OK
OK
---
Reference:
X
Details (p.619)
Mid$
Extracts a part from the
character string
String
Operation
OK
OK
OK
OK
Reference:
X
Details (p.621)
Mkdir
Builds a directory
File Control
OK
OK
OK
OK
Reference:
X
Details (p.623)
MOD
Gets the remainder
Arithmetic
Calculation
OK
OK
OK
OK
Reference:
X
Details (p.624)
MoveUnit
Moves a processing unit
Flow control
---
OK
OK
---
Reference:
X
Details (p.625)
NOT
Gets the "not" result (negation)
of the expression
Arithmetic
Calculation
OK
OK
OK
OK
Reference:
X
Details (p.626)
Command
Name
Function
Classification
Unit
Calculat
ion
Macro
Scene
Control
Macro
Commu
nication
Comma
nd
Macro
Unit
Macro
References
Summary of Contents for fh-1 series
Page 8: ...WWW NNC IR 6 Vision System FH FZ5 Series User s Manual Z340...
Page 14: ...WWW NNC IR 12 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 22: ...WWW NNC IR 20 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 48: ...WWW NNC IR Initializing the Controller 46 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 68: ...WWW NNC IR Editing Scene Groups 66 Vision System FH FZ5 Series User s Manual Z340 MEMO...
Page 881: ...WWW NNC IR...